Full examination of fuel, gas, electrical, ventilation and safety equipment.
Maintenance/Repair Details:
Examination carried out by Graham Daniels (BSS Examiner) and as one would expect with a classic vessel of 56 years on the water there are a few things we need to put right before issue of a new certificate.
To date have already started by correcting the issue with the saloon ventilation vents by removing the blocked fly mesh. Sourced a possible replacement of the LPG cooker due to the current one not reaching current safety standards and slowly worked our way through the short list of tasks.
20th Aug 2024: All jobs completed. 😊
Remove blocked ventilation mesh in saloon roof vents. (Advised)Fit new CO alarm in rear cabin.Replace old cooker for new one with flame cut-out.Securing wobbly pipe work Gas/Fuel.Replace fuel filter drain plugs with metal ones.Reposition fuel tank vents to remove U bend likely to retain diesel fuel.Remove disused fridge gas pipe and valve. (Advised)Seal gas pipe outlet in gas container.Replace gas bubble tester fluid. (Advised)